Guidance 4D probe; recognize the probe by means of the ID code; swap the 4D push sign through the electrical relay to make the 4D probe do the job Commonly. 4.two.two Most important board The main board may be divided into two elements: entrance-finish of the primary board and again-stop of the primary board.
Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat detail login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
Get a whole and extended check out of the anatomical construction through panoramic imaging coupled with velocity indication and ahead/backward scan skill creating scanning less of a challenge, smoother and more controllable.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
By continuing your go to on our Internet site, you might be consenting to our use of cookies. On the other hand, you can alter your cookie options Anytime. Cookie choice Accept and Continue
Once you quit the scanning and the picture seize, you ought to power from the program and disconnect the procedure through the AC power provide, then pull out AC electrical power cables. Webpage 109: Battery Connecting Board
The chapter supplies the method to verify major operate and functionality of products. This is often only useful for reference, not preventive execution. Purpose examining and tests of the part shall be performed by Mindray support engineers as well as the person collectively. Page 66: Common Exam
Uncover far better diagnostic facts by way of extended look at of the anatomical composition on all convex probes.
Permits use of various scanned angles to kind just one picture, causing Improved contrast resolution and enhanced visualization
five.two.three Geometric positioning precision Longitudinal geometric positioning precision Check Move: Do adjustments as the best way in tests the maximum depth. Record the gap by 20mm Just about every section around the longitudinal targets line using the measurement caliper; Choose the value with the greatest error (to 20mm), estimate the precision using the formulation underneath The measurement caliper need to be positioned within the upper edge of the concentrate on, NOTE:... Webpage 79 Transverse geometric positioning accuracy Test Step: Include the scan surface on the phantom with water or couple gel, gently contact the probe Together with the scan floor Modify the depth, generating the transverse targets being displayed from the impression. Adjust the main target place to become posited beside the transverse targets (the conventional is just not obvious) Adjust parameters like attain, TGC, generating Just about every transverse targets to get Evidently displayed. Page 80 5.five.two.4 Blackout Space Exam Move: Go over the scan surface area of the phantom with drinking water or couple gel, gently Get hold of the probe with the scan surface Adjust the depth at a lower price, and set the focus at the nearest place to the scan surface. Minimize the worth of parameters like AP, Get until eventually the background sound just could be found. Website page 81: Program Improve And Servicing
Immediately after thriving connection, the freshly added community printer name will be demonstrated during the printer driver listing. NOTE: Prior to link the community printer, ensure the ultrasound method as well as printer are in the exact same community area, as well as the network is Doing work Generally. The IP deal with and the server name need to be valid, e.g. Website page forty seven DICOM Setting Enter the AE Title on the ultrasound procedure, port and PDU according to the true problem, and after that click on [Okay] to exit the display screen.
.. Page 161 The indicator within the printer Problems come about in the event the adapter turns orange, and also the printing printer adapter runs. Disconnect and link the fails. electric power adapter, electricity within the printer adapter once again, and verify whether the printing is regular following 1 moment. Webpage 163: Electrical Protection Inspection
Effectiveness Check five.five.one Exam Method Resolution Detection depth Geometric Situation Precision Blackout spot test Document the Test photos five.5.2 Exam Articles The image employed here is just for reference, keep on with the picture influence in the real Take note: problem. Demands: Screen: set the contrast and brightness on the scientific software benefit (or perhaps the default position) Procedure environment: dim home, simulating the clinical application ecosystem. Site seventy six In affliction the transverse resolution screening targets are horizontally displayed, document the minimum distance of two targets that can be Obviously acknowledged. Repeat the Procedure earlier mentioned for the transverse resolution screening targets at other depths. As proven in figure under. Axial resolution ... Website page 77 When using the convex probe, maintain the transverse resolution testing targets to notice: be exhibited close to the midline. When using a linear probe with steer functionality, tend not to turn on the steer operate when complete the transverse resolution exam. Zoom in the region where Dp50rb login the targets Positioned if important. The diameter of your concentrate on stage at a specific depth is equal to the transverse resolution with the depth. Web site 78 five.